description: Soushi Taninomiya, Daichi Kitamura, Norihiro Takamune, Kouei Yamaoka, Hiroshi Saruwatari, Yu Takahashi, Kazunobu Kondo, and Hayato Yamakawa, &quot;Demixing filter estimation for bleeding-sound reduction of a vocal microphone,&quot; Proceedings of Asia-Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC 2025), pp. 160–165, Singapore, Singapore, October 2025.
published: October 24, 25
canonical: https://www.docswell.com/s/8262029599/ZM68PX-2025-10-24-101616
---
# Page. 1

![Page Image](https://bcdn.docswell.com/page/37KW6WMN7D.jpg)

17th Asia Pacific Signal and Information Processing Association Annual Summit and Conference
Session: D3-1030-L1: Grand Challenge &amp; Audio Processing
Time: Thu., 24 Oct., 10:30-12:00 (UTC +7)
Demixing Filter Estimation for
Bleeding-Sound Reduction of
a Vocal Microphone
Soushi Taninnomiya , Daichi Kitamura s
Norihiro Takamune , Kouei Yamaoka , Hiroshi Saruwatari s
Yu Takahashi , Kazunobu Kondo , Hayato Yamakawa s
National Institute of Technology, Kagawa College, Japan
The University of Tokyo, Japan
Yamaha Corporation, Japan


# Page. 2

![Page Image](https://bcdn.docswell.com/page/LJ3161YZE5.jpg)

Background
• Bleeding sound in live music performances
– Non-target sources are also captured, especially by Vo. microphone
Drums
(Dr.)
Bass
(Ba.)
Ba.
amplifier
Monitor
loudspeaker
FoH
loudspeaker
Monitor
loudspeaker
Monitor
loudspeaker
Vocal
(Vo.) Guitar
(Gt.)
Monitor
loudspeaker
Gt.
amplifier
FoH
loudspeaker
We address the problem of reducing
the bleeding sound in the Vo. microphone
2


# Page. 3

![Page Image](https://bcdn.docswell.com/page/8JDXVX547G.jpg)

Background
• Bleeding sound in live music performances
– Non-target sources are also captured, especially by Vo. microphone
Drums
(Dr.)
Close-miking
Monitor
Ba.
loudspeaker
amplifier
Bass
Vocal
(Ba.)
(Vo.) Guitar
Gt.
(Gt.)
amplifier
Monitor
loudspeaker
FoH
loudspeaker
Monitor
loudspeaker
Monitor
loudspeaker
FoH
loudspeaker
We address the problem of reducing
the bleeding sound in the Vo. microphone
3


# Page. 4

![Page Image](https://bcdn.docswell.com/page/VEPPVPGVE8.jpg)

Background
• Bleeding sound in live music performances
– Non-target sources are also captured, especially by Vo. microphone
Drums
Target source
(Dr.)
Bleeding sounds from non-target sources
Bass
(Ba.)
Ba.
amplifier
Monitor
loudspeaker
FoH
loudspeaker
Monitor
loudspeaker
Monitor
loudspeaker
Vocal
(Vo.) Guitar
(Gt.)
Monitor
loudspeaker
Gt.
amplifier
FoH
loudspeaker
We address the problem of reducing
the bleeding sound in the Vo. microphone
4


# Page. 5

![Page Image](https://bcdn.docswell.com/page/27V2Z26R7Q.jpg)

Conventional method
• Bleeding sound reduction problem
– is similar to a multichannel audio source separation problem
• Blind source separation (BSS)
– extracts audio sources from a multichannel mixture
– assumes that the mixing system is unknown and estimates the
demixing system
Source
signals
Vo.
Mixing
system
Observed
signals
Demixing
system
Known
Estimate
Estimated
signals
Gt.
Ba.
Dr.
Unknown
5


# Page. 6

![Page Image](https://bcdn.docswell.com/page/5JGR4RN67L.jpg)

Conventional method
• Independent low-rank matrix analysis (ILRMA) [Kitamura+, 2016]
– estimate frequency-wise complex demixing matrix using amplitude and
phase information
Demixing
matrices
Time
Estimated
spectrograms
The power spectrogram of
each source is modeled by
a low-rank matrix
Frequency
Frequency
Frequency
Observed
spectrograms
Channel
Tim
e
Time
Update demixing matrices so that estimated signals have
low-rank structure in time-frequency domain
The microphone are
widely spaced
Because spatial aliasing occurs,
bleeding-sound reduction using
ILRMA becomes difficult
6


# Page. 7

![Page Image](https://bcdn.docswell.com/page/47QVGVQ2EP.jpg)

Proposed method
• Characteristics of bleeding sound in live music performances
– Vo. microphone contains a large amount of bleeding sound
– Other microphones (Gt., Ba., Dr.) contain almost no bleeding sound
– These facts have been confirmed through acoustic measurements
• Semi-blind model
– assumes that microphone signals with little bleeding sound can be
treated as the source signals
– In live music performances, Gt., Ba., and Dr. microphones serve as
references
Vo.
source
Gt.
source
Ba.
source
Dr.
source
Observed
signals
Vo. microphone
Gt. microphone
Ba. microphone
Dr. microphone
7


# Page. 8

![Page Image](https://bcdn.docswell.com/page/KE4M5MNP71.jpg)

Proposed method
• Semi-blind ILRMA (proposed method)
– Introduce the semi-blind model into ILRMA
– Some parameters of the demixing matrix are fixed
Normal ILRMA
Semi-blind ILRMA
Introduce semi-blind model
(Gt., Ba., and Dr. are references)
Vo.
source
Vo. microphone
Gt. microphone
Ba. microphone
Dr. microphone
Gt.
source
Ba.
source
Dr.
source
The rows of the demixing matrix
corresponding to Gt., Ba., and Dr.
are fixed as constants
Number of parameters
to be estimated is
reduced, allowing for
more stable estimation
8


# Page. 9

![Page Image](https://bcdn.docswell.com/page/L718W85XJG.jpg)

Bleeding-sound reduction experiment
• Experiment overview
– Simulate observed signals from impulse responses measured on
actual live-music stage
– Apply following three methods for bleeding-sound reduction
Gamma-TCNMF [Mizobuchi+, 2025]
ILRMA
Semi-blind ILRMA (proposed)
1.95 m
– Compare and evaluate in SDR improvement of Vo. microphone
1.80 m
4.00 m
8.00 m
11.9 m
A stage with a height of 0.5 m
0.25 m
Ba. 1.00 m
0.95 m
1.80 m
Vo.
Dr.
4.00 m
1.95 m
1.80 m
Gt. 1.00 m
15.8 m
9


# Page. 10

![Page Image](https://bcdn.docswell.com/page/G7WZ6Z5K72.jpg)

Bleeding-sound reduction experiment
• Results
– 3 dry sources x 30 initializations
Conventional methods
Proposed
method
The proposed semi-blind ILRMA clearly outperforms the other methods
and achieves significant bleeding-sound reduction
10


# Page. 11

![Page Image](https://bcdn.docswell.com/page/4JZ1Y1NNE3.jpg)

Conclusion
• Purpose
– Reducing the bleeding sound in Vo. microphone
• Problem
– ILRMA failed to bleeding-sound reduction
• Phase information cannot be accurately measured due to spatial aliasing
• Proposed method
– Focusing on the characteristics of live musical performances
• Vo. microphone contains a large amount of bleeding sound
• Other microphones (Gt., Ba., Dr.) contain almost no bleeding sound
– Introducing a semi-blind model into ILRMA
• This model aligns well with the live music performances
• Reducing the estimated parameters to ensure stable estimation
• Proposed method outperformed conventional methods
– Demonstrating the effectiveness of the proposed method using actual
measurement data
Thank you for your attention.
11